The PM 6750 is a six parameter Bluetooth module which includes SpO2, Pulse Rate, ECG, NIBP and Resp functions. It can be connected by serial RS232, Bluetooth or USB.

Features
- This device can be connected to computers and other devices via COM, Bluetooth or USB to transmit data and corresponding analysis.
- Stable in timely upload of patients’ data.
- Accessible for hospitals, community medical centers and family wards
- Integrates to legacy systems
- Ideal for Telemedicine consultation
Characteristics
- Linux and windows compatible
- Cloud data storage
- Online web access to historic data
- Stream data to multiple devices at real time
- Automatic backup of data
- Secure data end to end
- Encrypted data storage
Specifications
Physical Dimensions
| Length: | 12cm |
| Width: | 12cm |
| Height: | 2cm |
| Weight: | 80g |
Environment
| Temperature | |
| Operation temperature: | 5 ~ 40°C |
| Transportation and storage temperature: | -20 ~ 55°C |
| Humidity | |
| Operation Humidity: | ≤85% |
| Transportation and storage humidity: | ≤93% |
| Height above sea level | |
| Operation height above sea level: | -500 ~ 4,600 meters |
| Transportation/storage height above sea level: | -500 ~ 13,100 meters |
Specification
| ECG | |
| Full lead: | I, II, III, aVL, aVR, aVF and V1,V2,V3,V4,V5,V6 |
| Gain: | 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV |
| Scanning speed: | 12.5mm/s, 25mm/s and 50mm/s |
| Band width: | 0.05Hz ~ 100Hz(3dB) Diagnostic mode 1 ~ 40Hz Monitor mode 0.1 ~ 25Hz Operation mode |
| Heart rate | |
| Scope: | 0 times/minute to 250 times/minutes |
| Accuracy: | ±2 time/minute |
| SpO2 | |
| Measurement scope: | 35%-100% |
| Accuracy: | ±2% in the range of 90% ~ 100% ±3% in the range of 70% ~ 89% |
| NIBP | |
| Measurement method: | Electric oscillator |
| Cuff inflation time: | less than 15 seconds |
| Initial inflation pressure: | Dynamic state 24kPa (180 mmHg) |
| Measurement range: | Systolic blood pressure:4kPa ~ 34kPa (30mmHg ~ 255mmHg)Diastolic pressure:2kPa ~ 29.3kPa (15mmHg ~ 220mmHg)Mean pressure:2.7kPa ~ 31.3kPa (20mmHg ~ 235mmHg) |
| Measurement accuracy (Static pressure): | ±3mmHg |
| Resp | |
| Measurement methods: | Chest impedance method or concentration of carbon dioxide at end of respiration |
| Range of chest impedance method: | 0 time/minute ~ 100 minutes/minute |
| Accuracy of chest impedance method: | ±2 time/minute |
| Temp | |
| Single/double path | |
| Type: | Vascular/surface temperature |
| Scope: | 20°C ~ 50°C |
| Accuracy: | ±0.2°C |